R911383027 (HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Rated Current
18 Amps
Control Panel Type
Standard
Firmware
Ordered Separately
Mounting
Vertical inside control cabinet
Placement
Rear side attachment to mounting surface
Temperature Range for Rated Output
0 - 40 degrees Celsius
Ambient Temperature Range
40 - 55 degrees Celsius
Ethernet Communication
Integrated Multi-Ethernet
Encoder Interface
Integrated multi-encoder interface
Safe Motion Technology
Support Available
Frequently Asked Questions
What are the primary electrical parameters of this controller?
It operates with a 3×AC 200–500 V input and delivers 7.6 A output current. This configuration provides flexibility for diverse industrial motor and drive setups.
How does the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW manage voltage fluctuations?
It maintains operational stability within a ±10% voltage tolerance range. This capability protects internal electronics and ensures reliable torque output under unstable supply conditions.
What control voltage and power requirements are specified?
The controller uses a 24 V ±20% control voltage and consumes around 34 W. This low auxiliary demand simplifies integration into compact automation panels.
How is frequency range configured for motion control applications?
Its output frequency spans from 0 to 1600 Hz for precise motion scaling. This wide range enables optimized speed control across various synchronous and asynchronous motors.
What short-circuit and protection characteristics are defined?
It carries a 42 kA rms short-circuit current rating per UL 508C. This rating supports robust circuit protection coordination and enhances overall electrical system safety.
Common Misspellings
HCS011EW0018A03BETECEMS5NNFW
HCS01 1E W0018 A 03 B ET EC EM S5 NN FW
hcs01.1e-w0018-a-03-a-cc-ec-cn-l3-nn-fw
HCS1.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW
Internal Product Review
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW drive controller offers MultiEthernet communication and dual encoder interfaces for precise feedback control. It operates on 3× AC 200–500 V with an 18 A peak current and uses internal air cooling. This version is commonly applied in packaging automation, robotic material transfer, and synchronized motion systems in production environments.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW.
Want to 