R911387940 (HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW)

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The Bosch R911387940 (HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW) is an industrial drive controller from the HCS01 series intended for precise management of motor speed, torque, and position. It features a multi-encoder interface compatible with IndraDyn, Hiperface, EnDat 2.1/2.2, and MSM encoders, and integrates internal air cooling via an integrated blower, necessitating appropriate cabinet sizing due to internal warm air production. The controller operates with 3-phase AC input voltage of 200 to 500 V (±10%), supports a peak current of 8 A, and is enclosed in an IP20-rated casing, providing protection against solids of 12 mm and larger, but no moisture ingress. It includes a Multi-Ethernet communication interface, a standard control panel connection (not hot-pluggable), an engineering port, and a safety module for motor parameter monitoring. Operation is specified within an ambient temperature range of 0 to 40°C, with functionality degraded above 55°C. Firmware is supplied separately.

Technical Specifications

Function
Industrial Drive Controller

Encoder Interface Compatibility
Hiperface, EnDat 2.1, MSM encoder, resolver etc.

Cooling Method
Forced Air

Ambient Temperature Requirement
0 to 40 degrees Celsius

Maximum Allowable Temperature
55 degrees Celsius

Peak Current Output
8 Amps

Power Input Acceptance
200 to 500 Volts AC

Protection Class
IP20

Panel Support
Does not support hot-plug

Firmware
Ordered Separately

Installation Recommendation
Trained Personnel Only.

How should cooling be arranged for HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW?

Keep the blower intake and exhaust clear and provide filtered cabinet ventilation to maintain thermal margins. Regular blower and filter maintenance prevents thermal derating and preserves expected component lifetimes.

What encoder protocols interface with HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW?

It supports Hiperface and EnDat encoders for precise position feedback and improved loop dynamics. That accuracy is crucial for high-speed synchronization and repeatability.

How does BASIC control section pairing affect deployment for HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW?

BASIC pairing sets convenient defaults to simplify commissioning while retaining essential tuning options. This helps teams bring machines online faster with less specialized setup effort.

What is the recommended firmware approach for HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW installations?

Maintain a controlled firmware registry and validate releases on a test bench before fleet rollout. Detailed change logs and rollback strategies reduce risk and speed recovery if issues arise.

What installation environment suits HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW?

Install inside ventilated indoor cabinets away from dust and moisture to maintain the IP20 protection assumptions. If the production area has contaminants, add protective enclosures or filtration to keep electronics and blower reliable.

HCS011EW0008A03BETECEPS5NNFW

HCS01 1E W0008 A 03 B ET EC EP S5 NN FW

hcs01.1e-w0008-a-03-a-cc-ec-ec-l4-nn-fw

HCS1.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW

Internal Product Review

Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW emphasizes mains tolerance and steady closed-loop delivery in variable supply environments. Its internal design stabilizes drive behavior under fluctuating supply conditions, reducing the need for external power conditioning in many industrial sites.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-S5-NN-FW.