R911391157 (HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW)
HCS IndraDrive Controllers
Technical Specifications
Product
Drive Controller
Optional Modules
Safety Module, Engineering Port
Input
Three-phase, 200 to 500 Volts AC
Maximum Current Output
8 Amps
Enclosure Rating
IP20
Mounting
Vertical, Inside Cabinet
Air Release
Inside Control Cabinet
Installation
By Trained Personnel Only
Frequently Asked Questions
How does STO function on the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW to provide emergency stops?
STO removes the drive’s capability to generate torque when a safety condition is asserted, ensuring motors cannot produce motion. This rapid torque cut is central to personnel safety during maintenance cycles and emergency events.
What panel density benefits does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW offer?
Its compact converter footprint preserves valuable cabinet space while still providing the necessary safety function. This enables denser control layouts for OEMs with constrained panel real estate.
How should thermal performance be monitored on the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW?
Track operating temperatures during representative duty cycles and inspect the blower periodically for dust buildup or bearing wear. Predictable thermal management preserves component life and prevents thermal derating.
How does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW interact with supervisory safety systems?
The drive reports safety state and alarms over the network, allowing supervisory systems to log events and alert operators. Integrate these signals into the safety management workflow for rapid incident acknowledgement and response.
What commissioning documentation is recommended for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW?
Provide test records of STO functions, wiring schematics, firmware revision notes and baseline parameter exports. These deliverables support traceable installations and make future audits and modifications straightforward.
Common Misspellings
HCS011EW0008A03BETECEPL4NNAW
HCS01 1E W0008 A 03 B ET EC EP L4 NN AW
hcs01.1e-w0008-a-03-a-cc-ec-cn-l3-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW combines Safe Torque Off with compact packaging to enable compliant emergency stops in high-density control cabinets. It supports safe maintenance without compromising panel space or thermal performance.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW.
Want to 