1-888-551-3082 | 1-919-443-0207 sales@indramat-usa.com

R911391897 (HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW)

HCS IndraDrive Controllers

  Available
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The Bosch Rexroth Indramat R911391897 (HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW) is an HCS01 series drive controller designed as a compact, single-axis converter for applications including machine tools and automation systems. It supports a three-phase AC mains voltage input of 200–500V (±10%) and has a device peak current of 54A. The controller weighs 4.60 kg, features air internal cooling via an integrated blower, and operates at ambient temperatures up to 40°C. The MPN provides encoder interfaces for IndraDyn Hiperface/EnDat 2.1/2.2 as well as encoder emulation, with signals isolated from the circuit board. It incorporates MultiEthernet communication, supporting sercos III, PROFINET IO, EtherCat, and EtherNet/IP, and includes a BASIC control section and Safe Torque Off (STO) safety technology, supporting switching frequencies of 4 kHz, 8 kHz, or 12 kHz. The housing is classified as IP20.

Technical Specifications

Cool System
Internal cooling airflow

Encoder Interface
Multi-turn encoder

Operating Voltage
200V-500AC, three-phase

Max Ambient Temperature
40C

Encoder Emulation Interface
Yes

Communication Module
Multi-Ethernet master

Supported Bus Systems
Sercos III, PROFINET IO, EtherCat, EtherNet/IP

Control Section
BASIC

Safety Technology Module
Safe Torque (STO)

Max Current Rating
54A

Weight
4.60kg

Switching Frequencies
4kHz, 8kHz, 12kHz

What safety interface is available in HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW?

HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW has STO (Safe Torque Off).

What type of encoder is on interface 2 of HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW?

HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW uses Encoder emulation.

What communication interface does HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW use?

HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW uses MultiEthernet.

What is the mains voltage range of HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW?

HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW operates at 3 x AC 200...500 V ±10%.

What power supply unit does HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW use?

HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW uses infeeding/feeded power supply.

HCS011EW0054A03BETECEML3NNNW

HCS01 1E W0054 A 03 B ET EC EM L3 NN NW

hcs01.1e-w0028-a-03-b-et-ec-pb-s4-nn-fw

HCS1.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW

Internal Product Review

The HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW provides consistent performance and dependable control. Users trust its stability during prolonged use, appreciating how easily it fits into different setups. It is chosen for its predictable behavior, making it a solid option for applications that rely on reliable operation and smooth performance over time.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0054-A-03-B-ET-EC-EM-L3-NN-NW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo