R911393598 (HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW)
HCS IndraDrive Controllers
Technical Specifications
Product Line
IndraDrive HCS
Design
1
Power Supply Unit Type
Feeding
Cooling method
Forced-air cooling
Minimum Airflow
56 m3/hour
Ambient Temperature Range
0 to 40 degrees Celsius
Derated Operation Temperature
40 to 55 degrees Celsius
Air Inlet
Bottom side of the unit
Air Outlet
Top side of the unit
Recommended Spacing
90 millimeters on the top and bottom side
Housing Rating
IP20
Maximum Output Current
8 Amps
Input Voltage Range
200 to 500 Volts AC
Control Section
Basic
Interfaces
Integrated Multi-Ethernet and multi-encoder
Safety Module
Supports safe torque off
Control Panel
Advanced
Firmware
Ordered separately.
Frequently Asked Questions
What does STO provide on HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW?
STO on HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW cuts drive torque generation immediately during a safety event. It reduces the need for external interlock relays while ensuring safe conditions for maintenance and emergency stops under documented testing.
How should encoders be connected to HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW?
Use shielded, correctly pinned connectors for Hiperface or EnDat encoders and verify wiring continuity. Proper cable routing and grounding prevent noise, minimize intermittent errors and keep closed-loop control stable under dynamic loads.
What thermal safeguards are recommended for HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW?
Ensure unobstructed blower airflow, ambient monitoring and scheduled blower inspections to avoid thermal derating. These safeguards preserve component life and prevent thermal trips that would interfere with production cycles.
What network practices keep HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW deterministic?
Use dedicated VLANs for motion traffic, enforce QoS and avoid broadcast-heavy segments near controllers. These measures maintain low latency and predictable packet timing essential for synchronized multi-axis motion.
How should firmware be rolled out for HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW?
Validate firmware on staging rigs that mirror production profiles and perform staged deployments. Keep rollback images and device-specific version logs to ensure consistent behavior across all installed drives.
Common Misspellings
HCS011EW0008A03BETECNNL3NNAW
HCS01 1E W0008 A 03 B ET EC NN L3 NN AW
hcs01.1e-w0008-a-03-a-cc-ec-em-l3-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW
Internal Product Review
The Indramat's HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW embeds STO safety into a compact MultiEthernet drive. Its form factor fits retrofit cabinets while providing instantaneous electronic torque removal, simplifying safety wiring and preserving panel space too.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-NN-L3-NN-AW.
Want to 