R911400976 (HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW)
HCS IndraDrive Controllers
Technical Specifications
Encoder Interface
Multi-encoder
Functionalities
Safe Torque OFF and Safe Brake Control
Operation mode
Three-phase
Communication
Ethernet-based SERCOS III protocol
Control Section Design
Basic
Maximum Operating Temperature
55°C
Cool Down Time
15 minutes
Work Environment
Not Underwater
Input Parameters
1 Analog Input, 8 Digital Inputs
Adapter Box
SHL03.1 Hall sensor
Design
Standard
Leakage Current
Over 3.5mA
Environment Impact
Free of harmful materials
Backup Support
1 Year
Depth
196mm
Wiring Material
Copper
Supported PWM Frequencies
4kHz, 8kHz, 16kHz
Operating Conditions
Not outside the control cabinet
Vibration Amplitude
0.15mm peak-peak at 10Hz to 57Hz
Mounting
Allowed only in G1 orientation
Cooling Method
Natural convection
Delivery
Worldwide
Frequently Asked Questions
What advantage does the internal air cooling in the HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW provide?
The integrated blower ensures efficient heat dissipation without external cooling units. This promotes stable performance and minimizes maintenance efforts in confined installations.
How does the 28 A peak current capacity benefit motion applications?
It allows the drive to manage high torque and acceleration demands effectively. This ensures smoother, more dynamic operation under varying mechanical loads.
Does the IP20 rating limit where the HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW can be installed?
Yes, the IP20 rating is suitable only for dust-controlled indoor environments. It should be mounted in protective enclosures to avoid exposure to moisture or debris.
How does the BASIC (B) control section design enhance the performance of the HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW?
This design enables straightforward configuration and reliable operation within motion systems. It reduces setup complexity, making installation faster and maintenance simpler.
Do users need external cooling when operating the HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW in high-demand systems?
Generally, no - its internal air cooling efficiently manages standard thermal loads. However, additional ventilation can be added if the system operates in higher ambient temperatures.
Common Misspellings
HCS011EW0028A03BETECNNL4NNAW
HCS01 1E W0028 A 03 B ET EC NN L4 NN AW
hcs01.1e-w0028-a-03-a-cc-ec-et-sb-nn-fw
HCS1.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW
Internal Product Review
The HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW is a controller for precise motion control and automation. It provides a 28 A peak current, has internal air cooling through an internal blower, and incorporates protection with an IP20 rating. This controller is made by Bosch Rexroth Indramat and is compatible with a BASIC (B) control section design.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0028-A-03-B-ET-EC-NN-L4-NN-AW.
Want to 