HDS03.2-W100N-HA21-01-FW
HDS Drive Controllers
The Bosch Rexroth Indramat HDS03.2-W100N-HA21-01-FW is a high-performance module in the HDS Drive Controllers series by Bosch Rexroth Indramat. This Product Type offers robust control functionality within a compact footprint, designed for demanding industrial applications. Featuring a Controller Family designation of DIAX04, it delivers precision motion control with streamlined parameter management. Built on the proven HDS architecture, the HDS03.2-W100N-HA21-01-FW integrates seamlessly in automation systems, providing consistent performance across varied operating conditions.
Incorporating a Built-in Internal Air Blower Cooling Method, the controller ensures temperature stability even under peak loads, while its Rated Current capacity of 100 A supports high-torque motor operation. Communication is handled via a versatile Command Communication Interface set to ANALOG, facilitating real-time setpoint and feedback loops. The unit belongs to Line 03 and carries a Product Group code of HDS to denote its family lineage. Versioning details include Version 2 and a Version of Function ID of 1, with a unique Function ID Code of 21 and no Other Versions available for this exact configuration.
Engineers benefit from straightforward integration, as the HDS03.2-W100N-HA21-01-FW adapts easily to existing DC bus networks and control topologies. Its internal blower cooling and rugged design ensure long-term reliability in continuous-duty environments, minimizing downtime and maintenance. As part of the Indramat ecosystem, this controller enhances system responsiveness and scalability, making it ideal for packaging machinery, conveyor systems, and multi-axis gantries where precision and uptime are paramount.
Technical Specifications
Command Communication Interface
ANALOG
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Line
03
Other Versions
None
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
Function ID Code
21
Product Group
HDS
Version of Function ID
1
Frequently Asked Questions
What are common failure risks if cooling airflow is obstructed?
Restricted airflow leads to overheating, causing derating or thermal shutdown. In severe cases, it may damage IGBTs or control boards.
Does the analog communication interface limit modern automation integration?
Not necessarily, since analog setpoints remain widely used for velocity and torque control. However, additional converters may be needed for digital-only systems.
How is parameter management streamlined in this drive family?
Predefined parameter sets reduce commissioning time. Engineers can quickly adapt settings for different motor and load configurations.
In what environments is this unit typically deployed?
It is suited for packaging lines, conveyors, and gantry systems requiring fast, precise motion. Rugged design ensures uptime in high-cycle industrial processes.
How does version control (e.g., Function ID 21) impact maintenance?
Each function ID corresponds to specific firmware compatibility. Using the wrong version may cause communication errors or improper motor behavior.
Common Misspellings
HDS 03.2-W100N-HA21-01-FW
HDS03-2-W100N-HA21-01-FW
HDS03.2-W100N-HA21-01
HDS032W100NHA2101FW
HDS3.2-W100N-HA21-01-FW
HDSO3.2-W100N-HA21-01-FW
Internal Product Review
Bosch Rexroth Indramat manufactures the HDS03.2-W100N-HA21-01-FW which is a high-performance motion control module in the HDS Drive Controller family (DIAX04). It offers a 100 A rated current, internal blower cooling for thermal stability, and uses an analog command communication interface. This controller is widely used in robotics, packaging machinery, textile and handling machines, where precise torque, position and velocity control are required.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HDS03.2-W100N-HA21-01-FW.
Want to 