HDS03.2-W100N-HS70-01-FW
HDS Drive Controllers
Technical Specifications
Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Line
03
Other Versions
None
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
Function ID Code
70
Product Group
HDS
Version of Function ID
1
Frequently Asked Questions
Does the HDS03.2-W100N-HS70-01-FW need a separate power supply or can it run standalone?
It operates on a shared DC bus from an HVE/HVR supply module; plan the cabinet around L+ / L− connections and the drive’s short-circuit and fuse requirements. Typical W100N variants expect ~530–670 VDC bus and 500 VAC max output, so size upstream protection accordingly.
What cabinet layout keeps the internal blower effective?
When stacking drives vertically, install a baffle between rows so upper blowers don’t ingest lower exhaust; otherwise performance drops and overheating risk rises. Route cooling air so the unit doesn’t recirculate warm air and avoid condensation from cooling units.
Does switching frequency change how much continuous current the drive can deliver?
Yes continuous current capability drops as PWM frequency increases; W100N variants list ~50 A at 4 kHz versus ~35 A at 8 kHz. Plan thermal margins and motor sizing with that derating in mind.
How should I route motor and signal wiring to minimize EMI issues?
Separate signal from power runs, use shielded lines for analog/encoder signals, and terminate shields on the provided grounding/mounting hardware. Follow the supplied connector kit and torque specs to maintain EMC and safety.
Is this platform suitable for high-speed spindles or only axes?
W100N models support output frequencies up to ~1000 Hz, enabling high electrical speeds when matched to appropriate motors. Ensure motor voltage/frequency are within limits and that bus and cooling are sized for the duty cycle.
Common Misspellings
HDS 03.2-W100N-HS70-01-FW
HDS03-2-W100N-HS70-01-FW
HDS03.2-W100N-HS70-01
HDS032W100NHS7001FW
HDS3.2-W100N-HS70-01-FW
HDSO3.2-W100N-HS70-01-FW
Internal Product Review
The HDS03.2-W100N-HS70-01-FW is a drive controller by Bosch Rexroth Indramat with a 100 A rated current and built-in internal air blower for cooling. It works with DIAX04 controllers and supports the SERCOS communication interface. This product is ideal for industrial automation and machine control in various manufacturing sectors.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HDS03.2-W100N-HS70-01-FW.
Want to 