HDS03.2-W100N-HT14-01-FW
HDS Drive Controllers
Technical Specifications
Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Line
03
Other Versions
None
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
Function ID Code
14
Product Group
HDS
Version of Function ID
1
Frequently Asked Questions
What are the effects of a 100 A rated current in the HDS03.2-W100N-HT14-01-FW from Bosch Rexroth Indramat on cable sizing and DC bus requirements?
You’ll need power and motor cables capable of handling peak currents without excessive voltage drop or heating, and the DC bus supply must provide clean, stable voltage under full load so the controller doesn’t enter undervoltage or derating conditions.
What cooling performance and placement issues arise with the internal air blower in a cabinet environment?
The built-in blower forces airflow internally but still requires ambient clearance and proper orientation to avoid heat buildup; positioning must allow fresh air intake and exhaust without obstruction to prevent overheating under continuous use.
How does the IP10 protection rating limit possible environments for this controller?
IP10 gives protection against large bodies (like hands) but offers almost no protection against dust or water ingress; thus, the controller must be installed in clean, dry control cabinets, ideally with filtered airflow if dust is present.
What diagnostic or safety features should one plan for when integrating this type of drive controller?
One must include measures for holding brake control, motor temperature monitoring (via PTC/NTC), proper shielded feedback wiring, protecting against EMC, and ensuring error‐shutdown paths (e.g. overcurrent, overheating, communication loss).
How does versioning (function ID, firmware etc.) affect compatibility and replacement parts for the HDS03.2-W100N-HT14-01-FW?
Matching firmware version, function ID, and all configuration codes is essential to ensure calibration, safety parameters, and communication protocol behavior align; using a mismatched version may lead to drive faults, disagreement in diagnostic data, or degraded performance.
Common Misspellings
HDS 03.2-W100N-HT14-01-FW
HDS03-2-W100N-HT14-01-FW
HDS03.2-W100N-HT14-01
HDS032W100NHT1401FW
HDS3.2-W100N-HT14-01-FW
HDSO3.2-W100N-HT14-01-FW
Internal Product Review
The HDS03.2-W100N-HT14-01-FW drive controller from Bosch Rexroth Indramat is designed for DIAX04 controllers with a SERCOS communication interface. It offers a 100A rated current and features internal air blower cooling for efficient operation. This product is commonly used in automation, robotics, and manufacturing industries for precise motor control.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HDS03.2-W100N-HT14-01-FW.