The Bosch Rexroth Indramat HMS01.1N-W0350-A-07-NNNN inverter from the HMS Axis Inverters series is a high-performance Single Axis Inverter designed for industrial automation. Featuring internal air with integrated blower cooling, it operates on a nominal DC bus voltage of DC 700 V and an input voltage range of 254 to 750 V DC with an input current rating of 115 A and a rated maximum current of 350 A. Protected to IP20 and rated for operation from 0 to +40 °C, it consumes 218 W and uses a 24 V control voltage. Fully compatible with MLD automation systems, this HMS unit ensures stable operation during malfunctions.

Technical Specifications

Cooling Type
Internal Air with Integrated Blower

Design Version
1

Internal Power Supply
Not Equipped

Line Version
1

Nominal DC Bus Voltage
DC 700 V

Product Type
HMS

Protection Class
IP20

Rated Maximum Current
350 A

What cooling requirements should be met to ensure reliable thermal performance of the HMS01.1N-W0350-A-07-NNNN (Bosch Rexroth)?

To maintain safe junction temperatures, adequate airflow through the internal blower is needed and ambient temperature must remain within 0-40 °C; high duty cycles or reduced cooling airflow will require de-rating the current

What is the difference between constant current capability versus peak or rated maximum current in this inverter?

Although the driver can reach a maximum current of 350 A, its continuous (or “constant”) current rating is lower (≈ 250 A) to avoid thermal stress, so for sustained operation design for the continuous current limit.

What control voltage supply is required, and what are the implications of the unit not having an internal power supply?

The control and logic circuits require 24 V, but since the unit is “not equipped” with internal power supply, you’ll need an external 24 V source with enough capacity; failure or instability there can cause control malfunctions or loss of safety interlocks.

What safety grounding and wiring cross-section should be used with this inverter to satisfy UL / EMC and safety standards?

Motor connections and grounding must follow specified copper cross-section wire (material: Cu, conductor temp rating 60/75 °C), with proper grounding of the frame, ground straps, and EMC shielded cable to meet the EMC / UL specifications in the manual.

How much power dissipation (losses) should one budget for continuous operation at the rated constant current?

At continuous current and with nominal DC bus usage, power dissipation can reach up to ~2750 W based on UL specs for this power class, meaning substantial cooling and heat sink/enclosure design must be accounted for.

HMS 01.1N-W0350-A-07-NNNN

HMS01-1N-W0350-A-07-NNNN

HMS01.1N-W0350

HMS011NW0350A07NNNN

HMS1.1N-W0350-A-07-NNNN

HMSO1.1N-W0350-A-07-NNNN

HMS01 1N W0350 A 07 NNNN

hms01.1n-w0350-a-07-nnnn

Internal Product Review

The Bosch Rexroth HMS01.1N-W0350-A-07-NNNN is a HMS Axis Inverter designed for MLD automation systems, featuring a nominal DC bus voltage of 700 V and a maximum current of 350 A. It operates with an internal air cooling system and provides reliable performance with IP20 protection. This drive controller is ideal for applications in robotics, material handling, and manufacturing automation.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HMS01.1N-W0350-A-07-NNNN.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo