The KDA 2.1-100-3-L00-W1 from Bosch Rexroth Indramat features a rated current of 100 A and a DC bus voltage of 300 V. Part of the KDA Spindle Drives, it uses forced cooling via a heatsink blower and accepts speed commands over SERCOS interface. It requires a 220 VAC supply for the blower and omits auxiliary encoder input and interface.
It offers high stiffness, precise positioning and wide continuous speed range. The drive follows Design 1 standards. It is classified under Series 2.
AC Supply Source for Heatsink Blower
220 VAC
Aux. Encoder Input
Without
Aux. Interface
Without
Cooling
Forced Cooled by Heatsink Blower
DC Bus Voltage
300 V
Design
1
Product
KDA
Rated Current
100 A
Series
2
Speed Command Value
SERCOS - Interface