The KDA 3.1-050-3-DP0-W1 spindle drive is produced by Bosch Rexroth Indramat within the KDA Spindle Drives series. Designed to regulate high-speed machining spindles, this unit converts a fixed intermediate DC bus into a variable three-phase output so CNC controllers can maintain precise tool speed and torque profiles. As a dedicated spindle drive, it forms the axis-specific portion of an Indramat modular drive rack and relies on the central supply module for its DC link energy. Integration of the drive into automation lines allows synchronized spindle positioning during tapping, boring, or contour milling operations.
This model draws its main power from a 300 VDC bus and can deliver a continuous output of 50 A, giving it the current density required for medium-frame motor loads. The internal heatsink is cooled by a mounted heatsink blower supplied from an auxiliary line at 220 V/50-60 Hz; the blower prevents thermal saturation of the IGBT stack during extended high-speed cuts. Speed references arrive from the CNC as a Digital (16 bit parallel) word, so velocity resolution remains constant across the full operating band. Together, these electrical and cooling parameters let the drive maintain stable spindle RPM under dynamic chip-load changes.
Environmental and interface features round out the unit’s profile. Operation is specified between 5 to 45 °C, and installation is permitted up to 1000 m above sea level without derating, matching typical shop-floor conditions. Heat removal follows a forced cooling scheme provided by the onboard fan assembly, eliminating the need for cabinet air exchangers. A dedicated second encoder socket accepts feedback signals “for spindle feedback or additional motor feedback,” enabling dual-channel position verification when high precision threading or gear cutting is required. The drive ships with no additional interface option, and its designation “Series 3” indicates a firmware level aligned with later Indramat supply modules.
AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Additional Option
W1 (Standard version)
Ambient Temp Range
5 to 45 Degrees Celsius
Control
Digital
Cooling
Mounted Heatsink Blower
Cooling Method
Forced air cooling
Cooling Mode
Forced Cooling
Damping Option
DP0 (No internal damping resistor)
DC Supply Voltage
300 VDC
Dimensions
390 x 125 x 315 mm (H x W x D)
Drive Type
Drive Controller
Feedback Type
Resolver or encoder compatible
Frequency
50/60 Hz
Input Voltage
380 – 480 V AC
Max Installation Elevation
1000M above sea level
Output Voltage
0 – 480 V AC
Phase
3-phase
Product Type
Spindle Drive
Protection Class
IP20
Rated Current
50 A
Second Encoder Input
For spindle feedback or add. motor feedback
Series
3
Speed Command Value
Digital (16 bit parallel)
Type
KDA 3.1
Weight
Approx. 11 kg