The Bosch Rexroth Indramat KDA 3.1-100-3-DY0-U1 is a spindle drive module released in the KDA Spindle Drives series and manufactured for CNC and general machining centers. It conditions energy from a shared DC bus, regulates spindle torque, and exchanges position data with higher-level controllers, giving automated systems precise speed control during drilling, milling, or grinding cycles.
An internal heatsink blower powered from 115V/50-60Hz maintains component temperatures, and that blower is physically integrated as a Mounted Heatsink Blower. The power electronics operate from a shared link voltage of 300 VDC, while the output stage can deliver a continuous spindle current of 100 A. Speed reference data is accepted through a parallel bus encoded as Digital (16 bit parallel), so numerical setpoints can be transferred without D/A conversion errors. Version 3 hardware retains the series’ forced-air design and includes no additional interface option, which simplifies cabinet wiring and aligns with applications that only require fieldbus communication through the main control rack.
The drive’s thermal envelope spans 5 to 45 Degrees Celsius, and its cooling system is classified as Forced Cooling, allowing full rated current without external chillers when ambient air is available. Reliable operation is specified up to 1000M above sea level; beyond that elevation derating is necessary because of reduced air density around the blower. Feedback integrity is enhanced by a dedicated channel that supports a second encoder input and synchronous input, letting the controller reconcile spindle position with a secondary measuring transducer when required. Because no optional interface card is fitted, cabinet planners can reserve slot space for I/O or safety relays instead of auxiliary communications.
AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Auxiliary Encoder Input
Auxiliary & synchronous inputs supported
Cooling
Mounted Heatsink Blower
Cooling Method
Forced cooling via heatsink blower
Cooling Mode
Forced Cooling
DC Bus Voltage
300 V
DC Supply Voltage
300 VDC
Heatsink Blower Supply Voltage
115 VAC
Max Installation Elevation
1000M above sea level
Product Model
KDA
Product Series
3
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Speed Command Interface
Digital 16‑bit parallel
Speed Command Value
Digital (16 bit parallel)
We offer a repair service for the KDA 3.1-100-3-DY0-U1.
Want to sell your KDA 3.1-100-3-DY0-U1?