The KDA 3.2-050-3-LQI-W1 from Bosch Rexroth Indramat provides a rated current of 50 A and a DC bus voltage of 300 V. Part of the KDA Spindle Drives series, this spindle drive features forced cooling by a heatsink blower and supports a SERCOS interface speed command value.
It includes an aux encoder input for 1 V sinusoidal encoding and an incremental encoder output for precise positioning. The drive runs on 220 VAC for the heatsink blower and delivers continuous power.
AC Supply Source for Heatsink Blower
220 VAC
Aux. Encoder Input
With Aux. Encoder Input for 1V Sinusoidal Enc.
Aux. Interface
Incremental Encoder Output
Cooling
Forced Cooled by Heatsink Blower
DC Bus Voltage
300 V
Design
2
Product
KDA
Rated Current
50 A
Series
3
Speed Command Value
SERCOS - Interface