The KDA 3.2-100-3-LQI-U1 from Bosch Rexroth Indramat offers a Rated Current of 100 A and a DC Bus Voltage of 300 V. Part of the KDA Spindle Drives, this drive is forced cooled by a heatsink blower and uses a 115 VAC supply for the blower.
It features an auxiliary encoder input for 1 V sinusoidal signals and an incremental encoder output as well as a SERCOS interface speed command value. The spindle drive delivers high stiffness and an extensive speed range.
AC Supply Source for Heatsink Blower
115 VAC
Aux. Encoder Input
With Aux. Encoder Input for 1V Sinusoidal Enc.
Aux. Interface
Incremental Encoder Output
Cooling
Forced Cooled by Heatsink Blower
DC Bus Voltage
300 V
Design
2
Product
KDA
Rated Current
100 A
Series
3
Speed Command Value
SERCOS - Interface