Type
Main Spindle Drive Controller
Cooling Type
Forced (Built-in blower)
Blower Voltage Input
115 Volts AC
Rated Current
150 Amps
Continuous Current Rating
90 Amps
DC Bus Voltage
300 Volts DC
Drive Weight
17.4 Kilograms
Blower Weight
4.2 Kilograms
Speed Command
Integrated Analog
Auxiliary Encoder Input
No Support
Auxiliary Interface
Available (16-bit parallel digital command value)
Serial Interface
Available
Operating Parameters Location
Control Panel
Drive Firmware Location
AS programming module
Enclosure Rating
IP 10
Installation Requirement
Trained Personnel Required.