Protection Level: IP 65
Maximum Bypass Current Rating: 25A
Operation Environment: Indoor
Connectivity Method: Daisy chain via hybrid cable
Encoder Type: Singleturn Hiperface Capacitive with 16 increments
Grounding Conductors: Two
Diagnostic LED Indications: H14 diagnostic LED, lights up in three colors
Firmware Feature: Easy startup mode for initial commissioning
Motor Thermal Class: 155 as per EN 60034-1
Communication: Supports MultiEthernet master communication
Replacement Criteria: Replacement with same type unit
Connector for Programming Module: X107
Holding Brake: Integrated, released through X141 interface
Post Commissioning Requirement: Drive parameters saved and archived
Motor Feature: Maintenance-free operation.