Climate Category During Transport: 2K3
Transportation Temperature: 20°C and 70°C
Installation: Near the Machine
Rated Voltage Input: 30VDC to 42VDC
DC Bus Capacitors Capacitance: 0.024mF
Mounting Requirements: Clean Surface
Flange Assembly: M10 Size Screws with 51Nm Tightening Torque
Signal Lines and Load Resistance Lines: Separate Laying
Analog Signals Transmission: Through Shielded Lines
Drive Termination: At Final Connection Point X103.2
Housing to Equipment Grounding: Through Flange
Motor Rotor Moment of Inertia: 0.00446 kgm2
Motor Thermal Time Constant: 25 Minutes
Motor Maximum Electrical Speed: 4,700min-1
Power Section Power Dissipation: 165W