Controller Type: Main Spindle Drive
Continuous Motor Output: 30kW to 52kW
Protection Level: IP 100 according to EN 60529 (DIN VDE 0470)
Current Type: 300A
Interface: SERCOS
Cooling: Built-in fan
Humidity Standard: F according to DIN 40 040
Controller Weight: 121kg
Mounting Frame (M1-RAC4) Weight: 2kg
Accessory (M2-RAC) Weight: 1.7kg
Continuous Controller Output: 55kW
Peak Controller Output: 55kW
Rated Connection Voltage: 3×AC 400V, 50Hz ± 15%, 3×AC 460V, 60Hz ± 10%
Continuous Regeneration Output: 37kW
Peak Regeneration Output: 55kW
Install Height: Up to 1000m above sea level
Permanent Ambient Temperature: 5°C to 45°C
Reduced Rate Ambient Temperature: Up to 55°C (at 80% rated data)
Storage and Transport Temperature: -30°C to 85°C
Transport Container: Included
Accessories: Included
Current and Insulation Standards: VDE 0160.