R911255904 (RAC 2.3-200-380-A0I-Z1)
RAC Spindle Drive Controllers
Technical Specifications
Product Line
RAC 2 spindle drive controller
Manufacturing Standard
DIN VDE 00160
Approximate Weight
121 kg
Peak Power Output
55 kW
Power Supply Requirement
3-phase, 3x400 volts, 50…60Hz ±15%
Current Rating
300 Amps
Speed Setpoint Interface
Analogue (+/- 10 V)
Heat Dissipation Mechanism
Control cabinet outside air with fan
Ambient Operating Temperature
5-45 °C
Maximum Installation Height
1000 meters above sea level
Ambient Humidity Rating
Class F (DIN 40 040 standard)
Protection Classification
IP 10
Storage Environment
Dry, dust-free, -30 to 85 °C
Transportation Requirement
Damping base, -30 to 85 °C temperature range.
Frequently Asked Questions
What is the rated connection voltage of the RAC 2.3-200-380-A0I-Z1?
The rated connection voltage of the RAC 2.3-200-380-A0I-Z1 is 3 × AC 400 V, 50–60 Hz.
Does the RAC 2.3-200-380-A0I-Z1 have an additional bleeder?
The RAC 2.3-200-380-A0I-Z1 operates with an additional bleeder.
What type of additional interface does the RAC 2.3-200-380-A0I-Z1 provide?
The RAC 2.3-200-380-A0I-Z1 provides an incremental encoder output as an additional interface.
What type of cooling does the RAC 2.3-200-380-A0I-Z1 use?
The RAC 2.3-200-380-A0I-Z1 uses internal blower / built-in fan cooling.
What is the rated current of the RAC 2.3-200-380-A0I-Z1?
The rated current of the RAC 2.3-200-380-A0I-Z1 is 200 A.
Common Misspellings
RAC 23200380A0IZ1
RAC 2 3 200 380 A0I Z1
Rac 2.3-200-380-a0I-z1
Internal Product Review
The RAC 2.3-200-380-A0I-Z1 offers enhanced thermal stability with a bleeder while delivering incremental encoder feedback. It is suitable for continuous, high-precision spindle operations.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the RAC 2.3-200-380-A0I-Z1.
Want to 