Producer: Indramat
Application: Numerically controlled machine tools
Rated Connections Voltage: 3 x AC 400V/50Hz, 3 x AC 460V/60Hz
Speed Set-point: Analogue (+/- 10 V)
Extra Encoder Input: No
Extra Bleeder: No
Cooling: Fan
Ambient Temperature Range: 5-45 degrees C
Maximum Permissible Operating Temperature: 55 degrees C
Maximum Installation Altitude: 1000 meters above sea level
Relative Humidity: 70% maximum average for the most humid month
Humidity Class: F (DIN 40 040 standard)
Mounting Accessories Needed: Yes, M1-RAC 2
Weight of Controller: 121 kg
Control Cabinet Preparation Required: Yes
Cooling Method Options: Inside air, Outside air, Hose cooling
Risk if Improper Cooling Arrangement: Condensation water ingress in controller
Shippable: Globally