RAC 2.2-250-460-DP0-W1
RAC Spindle Drive Controllers
The Bosch Rexroth Indramat RAC 2.2-250-460-DP0-W1 is part of the RAC Spindle Drive Controllers series, designed for precise control of asynchronous main spindle and frameless spindle motors. This AC Main Spindle Drive Controller supports a Rated Connection Voltage of 3 x AC 400 V, 50 Hz, +/-15% or 3 x AC 460 V and delivers a Rated Current of 250 A for robust power delivery. Its primary function is to manage spindle speed and torque with high reliability, making it ideal for CNC machining and high-precision industrial applications.
The controller features an Additional Encoder Input for spindle feedback and is compatible with a High-resolution INDRAMAT encoder (~) to ensure accurate position control. Signals are managed through a 25-pole Interface Terminal X4, while speed setpoints are issued via a Digital (16 bit parallel) Speed Command interface. Cooling is handled by an Internal Blower / Built-in fan, maintaining optimal operating temperatures under continuous load. The design omits an Additional Bleeder, simplifying the internal circuit layout and reducing maintenance points.
Constructed as a Series 2, Version 2 unit, the RAC 2.2-250-460-DP0-W1 offers seamless compatibility with standard three-phase supply networks at 400 V or 460 V. Its integrated cooling system and lack of additional bleeder components enhance durability and reduce downtime. The high-resolution encoder input and digital speed command ensure efficient, repeatable spindle positioning, while the robust interface terminal guarantees secure connections. In industrial settings the controller delivers consistent performance, improved spindle accuracy, and reliable operation under demanding conditions, contributing to increased productivity and reduced maintenance costs.
Technical Specifications
Rated Connection Voltage
3 x AC 400 V, 50 Hz, +/-15% or 3 x AC 460 V
Additional Bleeder
Without additional bleeder
Cooling
Internal Blower / Built-in fan
Device Type
AC Main Spindle Drive Controller
Rated Current
250 A
Additional Encoder Input
Additional encoder input for spindle feedback
Encoder Type
High-resolution INDRAMAT encoder (~)
Interface Terminal
X4, 25 poles
Series
2
Version
2
Speed Command
Digital (16 bit parallel)
Frequently Asked Questions
What is the rated connection voltage of the RAC 2.2-250-460-DP0-W1?
The rated connection voltage is 3 × AC 400 V, 50 Hz, ±15% or 3 × AC 460 V for the RAC 2.2-250-460-DP0-W1.
What type of additional encoder input does the RAC 2.2-250-460-DP0-W1 have?
The RAC 2.2-250-460-DP0-W1 includes an additional encoder input for spindle feedback.
What type of encoder is used in the RAC 2.2-250-460-DP0-W1?
The encoder type is a high-resolution INDRAMAT encoder (~) for the RAC 2.2-250-460-DP0-W1.
What is the rated current of the RAC 2.2-250-460-DP0-W1?
The rated current is 250 A for the RAC 2.2-250-460-DP0-W1.
What type of speed command does the RAC 2.2-250-460-DP0-W1 use?
The speed command type is digital (16-bit parallel) for the RAC 2.2-250-460-DP0-W1.
Common Misspellings
RAC 22250460DP0W1
RAC 2 2 250 460 DP0 W1
Rac 2.2-250-460-dp0-w1
Internal Product Review
The RAC 2.2-250-460-DP0-W1 combines high-resolution encoder feedback with digital control for smooth and consistent spindle operation. With a 250 A current rating, it is well-suited for precision-driven industrial applications.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the RAC 2.2-250-460-DP0-W1.