Condensation during operation, transport and storage
Not permissible
Pulse Frequencies
4kHz and 8kHz
Brake chopper
Not built-in
Cooling
Forced air with integrated liquid circulation
Components
Filter, heat exchanger
Required clear distance
At least 200mm above
Hoisting support points
2
Size class
G
Required distance between signal, power, motor and line supply lines
At least 20cm
Retained voltage after power OFF
Up to 5 minutes
Feedback implement
For cable dumping
Standby power supply
External 24V
Connection terminals during motor standstill
May be live
Busbar connector
Must be bolted
Motor connection terminals
Present on X2 connector
Cable Cross-section for motor and power supply connections
50mm2 to 150mm2
Fuse Type
gL
Maximum current rating
250A
Line Supply Connection
Three terminals on X1 connector
Shipment
Global.