R911201379 is part of the RD51 Drive Control Devices Series by Indramat Drives.


Specs
Overload Capacity: 60% for 60 seconds
Rated Output: 31 kVA
Output Frequency Range: 0 to 2000 Hertz
Nominal Output Current: 42 Amps
Rated Output Current: 52 Amps
Peak Current (60 seconds): 65 Amps
Continuous Output: 25 kVA
Peak Output (60 seconds): 39 kVA
Input: Three-phase 380 to 480 Volts AC
Environmental Class: 3K3
Operational Ambient Temperature Range: 0 to 40 degrees Celsius
Cooling Airflow Requirement: 0.3 cubic meters per second
Size Class: L
Ingress Protection Rating: IP20
Shipping Weight: 55 kilograms
Brake Resistor Peak Output: 49.6 kilowatts
Continuous Braking Power: 0.9 kilowatts
Brake Resistor Resistance: 13.3 Ohms
Chopper Power: 24.8 kilowatts
Chopper Minimum Resistance: 12 Ohms
Control Method: U/F curve control
Standby Power: 24 Volts
Operating Personnel: Trained personnel required