RECO-PC-104 B1 LK IBM 2
RECO Drive Modules
The RECO-PC-104 B1 LK IBM 2 is a communication controller board distributed by Bosch Rexroth Indramat within the RECO Drive Modules series. It occupies the master position on an INTERBUS fieldbus and is intended to coordinate decentralized I/O stations from a drive or motion control platform. By translating CPU-level commands into bus telegrams and collecting returning status data, the board streamlines deterministic signal exchange in industrial automation cells. Its compact layout allows direct stacking inside modular control racks where space is limited.
Electrically, the module follows the PC104 stacking standard, so it connects with adjacent processor cards through a self-supporting connector grid. Logic circuitry runs from a single +5 VDC rail, and typical current consumption remains near 400 mA, which reduces the load on backplane power supplies. An onboard diagnostic port uses RS-232C signaling, permitting parameter access with a handheld terminal. Field wiring leaves the card through a two-line RS-422 remote-bus driver that connects directly to shielded twisted-pair cables. Fixed addressing at 120h keeps the board in the reserved memory range of standard x86 targets, reducing setup time during system configuration.
As a network master, the controller can organize up to 256 remote bus segments across a hierarchy of 16 logical levels while supporting as many as 512 slave stations in total. Each segment may include 32 loop devices and can extend 400 m before a repeater is necessary. Digital process data capacity reaches 4096 input words and the same number of output words, providing ample room for valve terminals, drives, and sensor islands. When fiber-optic or copper repeaters are cascaded, the overall remote-bus reach extends to 12.8 km, allowing distributed machines to remain synchronized in large material-handling or packaging plants.
Technical Specifications
Board Format
PC104
Bus Role
INTERBUS Master
Current Draw
400 mA
Default I/o Address
120h
Diagnostic Interface
RS232C
Max Bus Segments
256
Max Device Levels
16
Max Devices
512
Max Inputs
4096
Max Loop Devices Per Segment
32
Max Outputs
4096
Max Remote Bus Length
12.8 km
Max Segment Length
400 m
Operating Voltage
+5 VDC
Remote Bus Interface
2-Line RS422
Type
Remote I/O
Frequently Asked Questions
What board format is used by the RECO-PC-104 B1 LK IBM 2 module?
The RECO-PC-104 B1 LK IBM 2 features a PC104 board format for embedded system integration.
What is the maximum number of devices supported by the RECO-PC-104 B1 LK IBM 2?
This module can control up to 512 devices as an INTERBUS Master.
What is the current draw of the RECO-PC-104 B1 LK IBM 2 drive module?
It has a current draw of 400 mA when operating.
How many inputs can the RECO-PC-104 B1 LK IBM 2 handle?
The RECO-PC-104 B1 LK IBM 2 supports a maximum of 4096 digital inputs.
What type of diagnostic interface is available on the RECO-PC-104 B1 LK IBM 2 module?
A diagnostic interface is provided via RS232C for troubleshooting and status monitoring.
Internal Product Review
The RECO-PC-104 B1 LK IBM 2 is a PC104 INTERBUS master module built for dependable industrial communication control. An RS232C diagnostic interface and +5 VDC operation support straightforward integration and efficient commissioning. Capacity for 512 devices and a 12.8 km remote bus length make the module an excellent choice for large distributed automation networks.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the RECO-PC-104 B1 LK IBM 2.
Want to 