Type Current
                                100A                            
                                Link Circuit Rated Voltage
                                300V DC                            
                                Cooling System Type
                                Built in fan or forced cooling method                            
                                Motor and Amplifier Combination Code
                                100                            
                                Input Coding
                                S102                            
                                Continuous Current
                                65A                            
                                Max Current
                                100A                            
                                DC Link Current Voltage
                                300 (± 15%)V                            
                                Power
                                30kW                            
                                Power Loss
                                400W                            
                                Current Consumption for Signal Processing
                                1450 [400]mA, 140mA and 60mA                            
                                Supply Voltage
                                220 or 115V                            
                                Frequency
                                50 Hz and 60 Hz                            
                                Power Consumption
                                30VA                            
                                Weight
                                10.5kg                            
                                Ambient Temperature for Use
                                +5⁰ to +45⁰C                            
                                Storage and Transportation Temperature
                                -30⁰C to +85⁰C                            
                                Maximum Altitude
                                1000m above sea level                            
                                Protection
                                IP10 per DIN 40 050                            
                                Insulation
                                Class C per DIN VDE 0110                            
                                Humidity Classification
                                F per DIN 40 040.                            
            
            
            
        
            
            We offer a repair service for the TDM 1.3-100-300-W1-000/S102.