2AD132D-B05OA1-AS01/S001
2AD 3-Phase Induction Motors
The 2AD132D-B05OA1-AS01/S001 from Bosch Rexroth Indramat features axial blower cooling and flange mounting. Part of the 2AD 3-Phase Induction Motors series, it delivers a nominal torque of 140 Nm and draws a nominal current of 54 A while operating at a base speed of 1500 min-1.
With a balance class of R, S, S1 and a noise level of 75 dB(A), it operates between 0 and 45°C. It weighs 135 kg and offers a holding torque of 100 Nm when electrically engaged.
Technical Specifications
Cooling Type
Axial Blower
Brake
Without holding brake
Motor Length Code
D
Mounting
Flange mounting
Power Connection Direction
To Side A
Nominal current
54 A
Moment of inertia (brake)
0.002 kgm²
Nominal torque
140 Nm
Nominal terminal voltage
24 ± 10 % V
Clamp delay (electr. engaged)
110 ms
Holding torque (Electr. engaged)
100 Nm
Operating temperature
0 … 45°C
Mass
135 kg
Base speed
"1500 min-1"
Balance class
R, S, S1
Air current
"B→A (blowing)"
Frequently Asked Questions
What is the impact of axial blower cooling on motor performance in the 2AD132D-B05OA1-AS01/S001?
Axial blower cooling allows consistent thermal regulation during prolonged duty cycles. This helps maintain torque stability and extends motor life under continuous or high-load operation.
Why is a holding torque of 100 Nm valuable in motion control systems?
It allows the motor to maintain position under load without continuous current draw. This is especially useful in vertical axes or safety-critical stopping scenarios.
Can the 2AD132D-B05OA1-AS01/S001 be used in ambient temperatures near 45°C?
Yes, but its performance margin narrows at the upper temperature limit. Ensure adequate ventilation to avoid thermal overload or derating.
What does a balance class of R, S, S1 indicate in practical terms?
It specifies rotor balance quality, affecting vibration and permissible speed ranges. Better balance minimizes mechanical stress and improves service life in high-precision systems.
How does clamp delay affect system responsiveness in the 2AD132D-B05OA1-AS01/S001?
A 110 ms delay impacts how quickly holding torque is applied electrically. This must be accounted for in timing-critical stop or lock sequences.
Common Misspellings
2AD132D B05OA1 AS01/S001
2AD132DB05OA1AS01/S001
2AD132D-B050A1-AS01/S001
2AD132D-BO5OA1-ASO1/SOO1
2AD132D-805OA1-AS01/S001
2AD132D-8O5OA1-ASO1/SOO1
2AD132DB050A1AS01/S001
2AD132DBO5OA1ASO1/SOO1
Internal Product Review
The Bosch Rexroth Indramat 2AD132D‑B05OA1‑AS01/S001 is a 3‑Phase Induction Motor. It features flange mounting, axial‑blower cooling, 140 Nm nominal torque at 54 A, 1500 min⁻¹ base speed, and 100 Nm electrically engaged holding torque. It is used widely in machine tools, printing, packaging and reshaping machinery.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the 2AD132D-B05OA1-AS01/S001.
Want to 