Use: Potentially explosive areas
Housing Design Standard: UL
Compatible Drive Controllers: DKCx.3 and HCS range
Motor Design Standard: EN 60079-0/1/31
Product Group: MKE
Commutation: Electronic
Frame Size: 118
Continuous Torque at 60K: 48Nm
Operating Temperature: 0°C to 40°C
Painting Restrictions: Do not repaint
Max Axial Shock Load: 10m/s2 for 6ms (DIN EN 60721-3-3 and 60068-2-6)
Holding Brake: 70Nm (electrically releasing)
Flange Side Protection: IP 65
Bearing Lifetime: 30,000 operating hours
Travel and Storage Restrictions: Avoid salt mist and direct solar radiation
Handling: Use lifting sling belts and eyebolts
Disassembly: Remove protective sleeves before assembly.