Allowable Ambient Temperature
0 to +40 °C
Allowable Storage And Transport Temperature
-20 to +80 °C
Coolant Temperature At Entry
10 to 40 °C
Insulation Classification
F
Maximum System Pressure
5 bar
Nominal Power Loss
2.5 kW
Pressure Drop At Required Coolant Flow
0.1 bar
Required Coolant Flowthrough
10 l/min
Thermal Time Constant
120 min
Volume In Coolant Channel
0.5 l
Weight (rotor)
14.5 kg
Weight (stator)
20.0 kg
Windings Inductance
0.55 mH
Windings Resistance At 20°c
0.07 Ohm