Cooling Methods
Natural or surface cooling
Continuous torque (Natural cooling)
Absent
Current at Standstill (Natural cooling)
10.4 Nm
Continuous Torque (Surface Cooling at 60K)
8 Nm
Continuous Current (Surface Cooling at 60K)
9.5A
Continuous Torque (Surface Cooling at 100K)
8.8 Nm
Continuous Current (Surface Cooling at 100K)
10.5A
Peak Current
38A
Max Torque
24 Nm
Voltage Constant at 20C
57V/min-1
Torque Constant at 20C
0.93Nm/A
Winding Resistance at 20C
0.8 Ohms
Max Speed
6000 min-1
Number of Poles
4
Winding Inductivity
8.6mH
Operating Temperature
0 to 400C
Thermal Time Constant
14 minutes
Leakage Capacitance
2.2nF
Rotor Moment of Inertia without Brakes
0.0008KgXm2