Or speak to a sales representative for additional information:
Performance Data Validity Range Ambient Temperature
0-40 degrees Celsius
Performance Data Validity Range Site Elevation
0-1000 meters
Output Derates Temperature
20% at 55 degrees Celsius
Output Derates Elevation
30% at 3000 meters
Humidity Class
3K4
Lowest-Highest Relative Humidity
5-95%
Lowest-Highest Absolute Air Humidity
1-29 grams per cubic meter
Max Rate of Temperature Change
0.5 degrees Celsius per minute
Max Axial Shock Load
10 meters per second squared
Max Radial Shock Level
1000 meters per second squared
Housing Protection Rating
IP65
Possible Protection Rating Increase
IP67 with sealing air kit
Mounting Style
Flange mounting with drive side up or down
Color
Black
Cooling Method
Natural convection
Optical Encoder
Singleturn with 128 signal periods
Electrical Connector
Rotatable by 240 degrees
Shaft Features
Keyway, shaft sealing ring
Holding Brake
Integrated, electrically releasing, 1 Nm rated