Ex-Design: Yes
Increased Run-Out and Concentricity: As per DIN 42955
Relative Air Humidity: 5% Low
Continuous Torque at Standstill: 28Nm
Encoder System: Optical
S3 Operation Mode: Present
Connection: Blind Plug Flushing
Use in Zone 2 and Zone 22 Atmospheres: Supported
Temperature Sensor: KTY84
Sensor Trigger Temperature: 140°C
Risks: Shearing, cutting, hitting
Additional Grounding Connection: With a 4mm2 Cross-Section
Flushing: Via Screwed Connections
Maximum Current Rating: 102A
Cooling Time: Approximately Five Times Thermal Time Constant
Installation: Upright with output shaft facing up or down
Holding Brake Voltage Rating: 24V +/-10%
Protection Classification: Explosion Protection (Indicated by X marking)
Interface: Multi-Turn Absolute Hiper-face
Temperature Limit: 55°C
Global Shipping: Available
Backup Support: One year from Wake Industrial