Use: General automation technology systems
Application: Potentially explosive areas
Product Group: MSK
Compliance: ATEX Design
Personnel Requirement: Trained and Qualified
Usage Restriction: Industrial Applications only
Housing Surface Temperature: Hot during operation
Grounding Connection: Additional with minimum 4mm2 cross-section
Maximum Temperature: 55°C with derated data
Cable Tensile Loading Limit: Should not be exceeded
Discharge Current: Flow over conductive housing parts
Holding Brake: Used only in standstill mode
Risk: Explosion hazards when overloaded
Certification: UL Listed and CSA Certified
Continuous Torque: 12Nm in standstill mode at 60K
Continuous Current: 5.2A in standstill mode at 60K
Maximum Axial Shock Load: 100m/s2 for 11ms
Shipping: Available globally