Windings Code: 450
Radial Force Based on Bearing Service Life: Yes
Liquid Accumulation Around Output Shaft: Not Allowed
Fitment of Drive Elements: Allowed
Load on Bearing Plus Shaft: High with Rigid Couplings
Motor Type Matching: Must Match Machine Design and Attachment Elements
Certifications: cUL Recognized, EAC Certified
Heat Dissipation: Reduced due to Contamination
Temperature Sensor: Included
Sensor Activates Shutdown at: 150°C
Temperature Sensor Monitored By: Drive Controller
Transportation Temperature Range: -20°C to 80°C
Mechanical Testing: For Axial Runout of Flange Surface to Shaft
Type-Plate: Unique
Backup Support: 1 Year from Wake Industrial
Lifting Straps around Shaft: Not Allowed
Inspection of Flange Holder: Needed Before Mounting
Runout and Concentricity: Increased as per DIN 42955
Power Cable Type: RGS1300
Encoder Cable Type: RGS1003
Connection: Established Only When De-energized
Cable Storage Requirement: Indoors in Dry Place
Delivery Packaging: Custom Military-Grade.