The Rexroth Indramat R911268887 (TVD 1.3-08-03) supply module is an innovative, durable, and efficient component of motion control products. This supply module has a frequency range of 50Hz to 60Hz, a DC bus voltage of 320 +/-5% V, and an input voltage of 3x 380 to 480 +/- 10% V. The module boasts maximum DC power of 22.5 kW for 0.3 seconds and sustained DC power of 7.5 kW. It features a bleeder with a continuous power of 0.5 kW and peak power of 20 kW, with maximum regenerated energy standing at 20 kWs. The unit's basic loss is 75W, and each continuous DC power incurs a 14W loss. With a net weight of 10.5 kg, it can operated at ambient temperatures of +5 to +45°C and stored or transported between -30 and +85°C. The maximum elevation for the module's use is 1000 MSL.
Frequency: 50Hz to 60Hz DC Bus Voltage: 320 +/-5% V Input Voltage: 3 x 380 to 480 +/- 10% V Maximum DC Power (0.3 seconds): 22.5 Kw Continuous DC Power: 7.5Kw Bleeder Continuous Power: 0.5 kW Bleeder Peak Power: 20 kW Maximum Regenerated Energy: 20 kWs Basic Loss: 75 W Power Loss per Continuous DC Power: 14 W Net Weight: 10.5kgs Max Permissible Ambient Temperature (With Derated Data): 550C Ambient Temperature with Rated Data: +5 to +450C Storage/Transport Temperature: -30 to +850C Maximum Mounting Height: 1000 MSL