SM13 109-0700-4A06-02 , Bosch Rexroth Indramat, SM AC Inverters inverter delivers precise motor control in industrial automation environments. This robust unit accepts three-phase 380–480 V AC input and operates at both 50 Hz and 60 Hz, offering seamless integration into global power systems. Designed for durability, it features a high-precision resolver encoder interface for closed-loop position and speed feedback. Built on the proven Indramat SM architecture, it meets demanding reliability standards while maintaining a compact footprint.
Detailed technical performance is provided through a Speed Regulating Range of >1:10,000 and a Control Input Type of differential ±7 to ±11 V for SW1. The inverter’s Dc Link Voltage spans 460 V rated to 700 V max, and Cooling Method is forced ventilation via a 24 V DC axial blower drawing just 100 mA. Continuous operation supports a Rated Current (continuous) range of 5 A–50 A depending on variant, while Peak Current capability extends to 100 A for dynamic load demands. With a Maximum Power Loss between 60 W and 350 W and a Torque Current Reduction Factor of 1.2% per °K above 45 °C ambient, the drive balances thermal efficiency and performance. An IP 00 Protection Class housing conforms to DIN 40050 and IEC 144, and the allowable Maximum Operating Temperature of 0 °C to 55 °C ensures stable output under factory conditions.
Integration is simplified through built-in Monitoring Functions for speed limits, motor temperature, and tacho fault detection, with Profibus and CANopen connectivity adding transparent diagnostics. Modular construction with maintenance-friendly replaceable units reduces downtime and streamlines field servicing. Well-suited to packaging machines, material handling systems, and machine tools, the SM13 109-0700-4A06-02 excels at delivering precise, reliable drive control in the most demanding industrial applications.
Admissible Humidity
Class F and DIN 40040
Control Input Type
Differential command inputs ±7 to ±11 V for SW1
Cooling Method
Forced ventilation with 1 axial blower, 24 V DC, 100 mA
Dc Link Voltage
460 Vrated to 700 Vmax
Max Operating Height
1000 m amsl
Max Storage Temperature
-25°C to +70°C
Maximum Operating Temperature
0°C to +55°C
Maximum Power Loss
60 W to 350 W depending on the variant
Model Prefix
SM
Monitoring Functions
Speed (min/max), motor temperature, tacho fault, etc.
Peak Current
10 A - 100 A depending on model variant
Protection Class
IP 00 to DIN 40050 and IEC 144
Rated Current (continuous)
5 A - 50 A depending on model variant
Speed Regulating Range
> 1:10,000
Torque Current Reduction Factor
1.2% per degree K above 45°C ambient