Or speak to a sales representative for additional information:
Connection
64-pole male multipoint connection, DIN 41612
Control Capabilities
Position control via force or overlaid pressure
Analog Current Inputs
0 to 20 mA or 4 to 20 mA
Current Input Resolution
5 microamperes
Bus Connection
Absent
Valve Output Stage
Absent
Modification of Outputs
Through amplification and adjustment
Digital Outputs
Can be configured to set internal and error flags
Fuse
4 A time lag
Minimum Working Voltage
21 V
Maximum Operating Voltage
30 V
Operational Temperature Range
0 to +50 degrees Celsius
Weight
0.2 kilos
Digital Position Transducer
SSI with RS485 line receiver
Front Plate Width
0.2 inches
Dimensions
100 x 160 mm
Storage Temperature Range
-20 to +70 degrees Celsius
Scan Rate
2 ms
Current Consumption
150 mA