Load During Transport: No Load
Storage Requirement: Shock-Free, Dry, Dust-Free Environment
Bb Contact Feature: Yes
Power Source: Charging Resistor
Required Service Cable: IKS0391
Feedback Cable Maximum Length: 75m
AS+ & AS- Control Inputs Power Rating: 1.5W
AS+ & AS- Control Inputs Voltage Rating: 20VDC to 30VDC
Starting Lockout Activation: 20VDC to 30VDC Voltage
RS 232 Serial Interface Connector: X2
Analog Diagnostic Outputs Voltage: 10VDC
Analog Diagnostic Outputs Current Rating: 4mA
Max Permissible Relative Humidity: 95%
Max Allowed Air Humidity: 25g/m3
Incremental Position Interface: Yes, in second slot
Storage and Transportation Temp: -30°C and 85°C
Installation: Vertical
L-, L+ & PE Terminals Tightening Torque: 3Nm
Operation with Unregulated Power Supply: Not Allowed.