Cooling System: Air-Cooled
Rated Output: 200 Amps
Heat Sink Location: Outside the cabinet
Heat Dissipation Inside Cabinet: 20%
Heat Dissipation Outside Cabinet: 80%
Enclosure Rating: IP20
Required Ambient Temperature Range: 0 - 45 degrees Celsius
Use Prohibited Above: 55 degrees Celsius
Ambient Temperature Output Derates: 45 - 55 degrees Celsius
Altitude Output Derates: Above 1000 meters
Use Prohibited Above Altitude: 5000 meters
Supported Motor Feedback: Digital Servo and Resolver
Mandatory feedback: SERCOS command communication interface
Software Module Slot: U5
Power Supply: 24 Volts DC
Installation: Qualified personnel only