The SUP-M01-DKCXX.3-040 from Bosch Rexroth Indramat features a design version 1 and an internal fan cooling type. Part of the DKC Drive Controllers, it handles a maximum circuit duration power of 12 kW at 3 × AC 480 V and supports control voltages from 19.2 to 28.8 V DC. It offers a cooling air flow of 150 m3/h and an input capacity of 0.9 to 1.2 mF.
It operates at 50/60 Hz and consumes between 19 and 21 W of power. Its operating temperature range spans +5 to +45 °C. With an insulation resistance over 25 MΩ, it ensures reliable performance under industrial conditions.
Design Version
1
Control Current Pulse Duration
12 ms
Control Voltage
(19.2 ... 28.8) V DC
Cooling Air Flow
150 m³/h
Cooling Type
Internal Fan
Coupling Capacity (power Section To Housing)
200 nF
Input Capacity
0.9 to 1.2 mF
Insulation Resistance At Dc500 V
> 25 MOhm
Maximum Circuit Duration Power At 3 X Ac 400 V
10.3 kW
Maximum Circuit Duration Power At 3 X Ac 480 V
12 kW
Maximum Inrush Current
4.0 A
Maximum Permissible Overvoltage
45 V for 1 ms, non repetitive
Operating Frequency
50/60 Hz
Operating Temperature Range
+5 ... +45 °C
Power Consumption (device Dependent)
19 - 21 W
Ripple (max)
Dependent on input voltage