The Bosch Rexroth Indramat HMD01.1N-W0020-A-07-NNNN from the HMD Double Axis Drive Controllers series delivers precision control for dual-axis applications, featuring a nominal DC bus voltage of DC 700 V and an effective peak current of 20 A to drive two motors with sustained performance. Built to IP 20 protection standards, this controller integrates natively with IndraDrive M and C systems for seamless automation solutions. Its compact cabinet-mounting design simplifies installation in existing racks and control cabinets. The device’s design version 1 and line version 1 ensure consistent build quality across production batches.
Reliability is reinforced by an internal air cooling method with integrated blower that maintains optimal thermal conditions within an operating temperature range of 0 to 40 degrees C. The controller tolerates up to 95% relative humidity and operates at altitudes up to 1000 meters without performance derating. Two motor outputs are monitored by activated overvoltage limiters above 33 volts to protect against voltage spikes, and an optional 24 V external power supply input supports auxiliary circuits. With no additional design features or power supply integration required, the unit remains straightforward to commission and maintain.
Engineered for demanding industrial automation tasks, the HMD01.1N-W0020-A-07-NNNN enables precise torque and speed synchronization across dual axes. Its robust feature set and compatibility with existing IndraDrive ecosystems reduce integration time and commissioning costs. This versatile double-axis inverter is an ideal solution for packaging, handling, and multi-axis coordination in modern manufacturing environments.
Cooling Method
Internal Air with Integrated Blower
Nominal DC Bus Voltage
DC 700 V
IP Degree of Protection
IP 20
Design Version
1
Effective Peak Current
20 A
Line Version
1
Additional Design Features
None
Power Supply Integration
None
Product Type
HMD Double Axis Drive Controller
Compatibility
IndraDrive M and C systems
External Power Supply
24V (optional connection)
Humidity Tolerance
Maximum 95% relative humidity
Maximum Operational Altitude
1000 meters
Mounting Type
Cabinet mounting
Number of Motors Controlled
Two
Operating Temperature Range
0 to 40 degrees C
Overvoltage Limiters
Activated above 33 volts