R911306439 (HMD01.1N-W0012)
HMD Double Axis Drive Controllers
Technical Specifications
Actors and Sensors Needed
Yes
Programming Required
Yes
Applicable Drive Types
Single and Multi-Axis
Separate Control Section
Yes
Control Section Includes
Basic Control Circuit Board and Interfaces
Optional Modules
Yes
Control Section Configurable
Yes
Factory Installed Control Section
Yes
Global Shipping
Yes
Frequently Asked Questions
What is the significance of the continuous vs. effective peak current rating on the HMD01.1N-W0012?
Continuous current defines what the drive can sustain indefinitely without overheating; the “effective peak” (12 A) allows short bursts (typically <60 s) for load surges or acceleration. Operating too long at or near peak current forces thermal derating or trigger of protection mechanisms.
How does the DC-bus voltage range (254-750 V) affect system design and safety margins?
A wide DC-bus range gives flexibility to use various rectifier modules or power supplies, but you must ensure upstream components (rectifier, capacitors) are rated for the highest DC level and transient overvoltage. Also, higher DC-bus voltage increases insulation requirements on motor cables and creepage distances.
What does the 0-800 Hz output frequency capability enable in real-world applications?
This range permits precision control over motor speed, especially in applications needing very high speeds (e.g., spindle drives, high-speed conveyors) or fine low-speed control; above standard 50/60 Hz use. But performance (torque, current capacity) may drop at extreme frequencies because of limitations in motor cooling and switching losses.
How should one interpret the Short Circuit Current Rating (42,000 A) for protection system coordination?
The SCCR defines the maximum fault current the device can safely withstand without catastrophic failure; protection devices upstream must have interrupting ratings above this value. Ensuring proper breaker or fuse sizing with appropriate breaking capacity is crucial to protect both the drive and the installation.
What is the meaning of “HMD01.1N-W0012 discharge time 30 minutes after power-off,” and when does it matter?
After you remove DC supply, the internal DC-bus capacitors will hold charge and take up to ~30 minutes to discharge to a safe level; it matters for safe maintenance or servicing to avoid electric shock. Always follow lock-out/tag-out procedures and ensure voltage has dropped before touching internal components.
Common Misspellings
HMD 01.1N-W0012
HMD011N-W0012
HMD011NW0012
HMD1.1N-W0012
HMDO1.1N-W0012
HMD01 1N W0012
hmd01.1n-w0012
Internal Product Review
The HMD01.1N-W0012 by Bosch Rexroth Indramat is a double-axis drive controller with 6.9 A output current and a frequency range of 0-800 Hz. It provides a 3-phase AC output up to 530 V and uses internal air cooling with an integrated blower. This controller is suitable for industrial automation, CNC machinery, and packaging systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HMD01.1N-W0012.
Exchange
Want to sell your HMD01.1N-W0012?