R911287552 (MHD115B-024-PP1-BA)
MHD Synchronous Motors
Technical Specifications
Type
synchronous motor
Current Consumption
32.3 and 37.9 A
Continuous Torque
50 and 57 Nm
Operating Conditions Temperature
0 to +40 degrees Celsius
Thermal Time Constant
45 minutes
Winding Resistance
5.3 ohms
Torque Constant
1.7 Nm/A
Installation Height
less than 1000 meters above sea level
Peak Torque
160 Nm
Winding Inductance
5.3 mH
Power Rating
14.4 kW
Rated Voltage
337 V
Maximum Torque
56.1 Nm
Cooling Method
natural and surface cooling
Weight
40 kg
Insulation Classification
F
Protection Classification
IP 65
Frequently Asked Questions
Is the MHD115B-024-PP1-BA liquid-cooled?
No, the MHD115B-024-PP1-BA is an air-cooled motor that relies on natural convection cooling to prevent overheating during operation. This ensures thermal stability without complicating system design.
What is the rated standstill torque for the MHD115B-024-PP1-BA?
The MHD115B-024-PP1-BA has a standstill torque of 50.0 Nm that supports position-holding tasks, ensuring that the motor can hold loads securely when not in motion.
Does the MHD115B-024-PP1-BA feature environmental protection?
Yes, the MHD115B-024-PP1-BA comes with ingress protection that ensures it is not susceptible to damage from dust, water or industrial contaminants. It is constructed to IP65 standards to ensure durability.
What shaft type is the MHD115B-024-PP1-BA equipped with?
The MHD115B-024-PP1-BA features a keyed shaft that is optimized for sound mechanical integration, ensuring stable torque delivery to the connected equipment.
What is the location of the power interface on the MHD115B-024-PP1-BA?
The power interface on the MHD115B-024-PP1-BA is located on Side B, providing a convenient connection point for power cables without requiring additional infrastructure.
Common Misspellings
MHD115B024PP1BA
MHD115B 024 PP1 BA
mhd115b-024-pp1-ba
Internal Product Review
The MHD115B-024-PP1-BA delivers outstanding reliability in tough conditions. Its integrated encoder ensures enhanced functionality. However, the natural convection cooling requires adequate ventilation consideration when setting up.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the MHD115B-024-PP1-BA.
Exchange
Want to sell your MHD115B-024-PP1-BA?