Or speak to a sales representative for additional information:
Design
Closed Motor
Bearings Lubrication
Grease
Intended Use
Main Drive or Servo Drive Motor
Voltage Constant
70V/1000min-1
Torque Constant
0.77Nm/A at 20°C
Brake
Not Included
Operating Temperature Range
0°C – 40°C
Storage and Transport Temperature Range
-20°C - 80°C
Insulation Class
Class F
Installation Height (Max)
1000m Above Sea Level
Rotor Inertia
8.7 x 10-4 kgm2
Cooldown Time
Approximately 140 minutes.