R911275578 (MKD112B-048-KP0-BN)
MKD Synchronous Motors
Technical Specifications
Motor Size
112
Shaft Length
B
Flange Size
192 mm
Centering Diameter
130 mm
Mass
34 kg
Rotor Moment of Inertia
192 x 104 kgm2
Continuous Standstill Torque
28 Nm
Rated Torque
7.7 Nm
Maximum Speed
3500 min-1
Operational Speed
2800 min-1
Rated Current
6.9 A
Terminal Voltage
227 V
Cooling Mode
Natural Convection
Shaft
With Keyway and Key according to DIN 6885-1
Protection Class
IP65
Electrical Connectors
Top-mounted, to the B-side.
Frequently Asked Questions
How much static holding is available for fixturing on MKD112B-048-KP0-BN?
It provides 28.0 Nm continuous torque at standstill. That capacity stabilizes clamped parts during long dwells or tensioned feeds, keeping position loops calm and minimizing thermal growth that could bias measurements in repeatable processes.
How does MKD112B-048-KP0-BN survive harsh bays with washdowns or airborne grit?
It meets IP65 protection class. Dust and water jets cannot penetrate the housing, preserving insulation resistance and resolver integrity so closed-loop control remains stable even when the surrounding environment demands frequent cleaning.
Which supply level should the inverter and protection coordinate around for MKD112B-048-KP0-BN?
It operates at 115 V nominal voltage. Matching bus hardware and drive modulation to that value maintains current headroom and switching efficiency, preventing saturation when the motion profile requires sharp accelerations or decelerations.
What property shapes acceleration tuning on MKD112B-048-KP0-BN?
It has 0.090 kgm² rotor inertia. That value tempers step responses, allowing assertive gains without overshoot, while still delivering crisp contouring in indexing tasks that combine frequent starts, stops, and reversals.
What ambient conditions should be assumed for enclosure and ventilation planning with MKD112B-048-KP0-BN?
It operates across 0 to 40 °C ambient. Cabinet airflow, cable derating, and load planning can align to this window to preserve winding life, avoid nuisance thermal trips, and maintain resolver accuracy.
Common Misspellings
MKD 112B-048-KP0-BN
MKD-112B-048-KP0-BN
MKD112B-O48-KPO-BN
MKD112B048KP0BN
MKD112B 048 KP0 BN
mkd112b-048-kp0-bn
Internal Product Review
MKD112B-048-KP0-BN brings steady motion for long-duty automation. The balanced electromagnetic design turns commands into smooth torque. Built for modular cells, it sustains accuracy, repeatability and efficient service through continuous shifts without adding complexity to the drive cabinet or maintenance overhead.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the MKD112B-048-KP0-BN.
Exchange
Want to sell your MKD112B-048-KP0-BN?