R911313002 (MKD090B-058-GG2-KN)
MKD Synchronous Motors
Technical Specifications
Characteristic Speed
4000 RPM
Rated Speed
4000 RPM
Peak Speed
5000 RPM
Continuous Torque at 60K Overtemperature
12 Nm
Continuous Current at 60K Overtemperature
17.2 Amps
Continuous Torque at 100K Overtemperature
12 Nm
Continuous Current at 100K Overtemperature
17.2 Amps
Peak Current
79 Amps
Voltage Constant at 20 degrees Celsius
0.81 Nm/A
Winding Resistance at 20 degrees Celsius
0.74 ohms
Winding Inductance
5.8 millihenry
Number of Pole Pairs
4
Housing Diameter
110 millimeters
Housing Length
313 millimeters
Motor Weight
14 kilograms
Feedback
Resolver
Shaft Type
Plain
Shaft Sealing Ring
Included
Holding Brake
Built-in
Holding Brake Torque
18 Nm
Holding Brake Current
0.71 Amps
Clamping Delay
16 milliseconds
Release Delay
90 milliseconds
Holding Brake Weight
1 kilogram
Peak Setup Height
3300 feet
Ambient Temperature For Operation
0 to 40 degrees Celsius
Ambient Temperature For Storage and Transportation
-20 to 80 degrees Celsius
Protection Against Vibrations
Required
Housing IP Rating
IP 65
Power Connection Output Direction
Terminal box on side B
Global Shipping
Available
Frequently Asked Questions
How does the MKD090B-058-GG2-KN ensure motion accuracy?
The MKD090B-058-GG2-KN maintains motion accuracy by using its integrated feedback to keep track of speed and positioning performance. This enhances accuracy in motion control for consistent system performance.
How is electrical connection done in the MKD090B-058-GG2-KN?
The MKD090B-058-GG2-KN offers a plug-in electrical connector that helps to keep the process of power integration setup without requiring complex configuration.
How much current does the MKD090B-058-GG2-KN draw during continuous operation?
The MKD090B-058-GG2-KN draws a current of 18.0 A, enabling stable performance in continuous operation.
What level of torque is generated by the MKD090B-058-GG2-KN to support high-load conditions?
The MKD090B-058-GG2-KN is capable of generating up to 75.0 Nm, providing substantial capacity for elevated load scenarios.
What type of cooling is integrated in the MKD090B-058-GG2-KN?
The MKD090B-058-GG2-KN integrates natural convection cooling to manage temperature conditions during operation. This maintains stable thermal performance for consistency in operation.
Common Misspellings
MKD090B058GG2KN
MKD090B 058 GG2 KN
mkd090b-058-gg2-kn
MKD90B-058-GG2-KN
Internal Product Review
The MKD090B-058-GG2-KN features a modest physical footprint that is a big plus in tight installations. Its performance remains stable even after extended duty cycles. However, since it is air-cooled, it is essential to ensure ample ventilation for thermal stability.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the MKD090B-058-GG2-KN.
Exchange
Want to sell your MKD090B-058-GG2-KN?