R911332004 (HMV01.1R-W0018)
HMV IndraDrive Supply Units
Technical Specifications
Component Type
IndraDrive controllers
Installation Environment
Closed cabinet control
Ambient Installation Temperature
-25-55°C
Storage Temperature
-25-55°C
Accepted Contamination Degree
(EN50178) 2
Steam and Dust Tolerance
EN50178 tab. A.2
Long-term Storage Care
Operate annually for a minimum of 1 hou
Frequently Asked Questions
What are the wiring implications when using the Bosch Rexroth Indramat HMV01.1E-W0120-A-07-NNNN in a centralized DC bus architecture?
Because the module is “feeded” (no intermediate rectifier), all drives share the same DC bus, so wiring must accommodate full 120 kW current plus good conductor sizing to reduce voltage drop. Also requires proper busbar or cable layout and possibly redundant paths for reliability in multi-axis systems.
What is the practical impact of IP20 protection in an industrial environment?
IP20 guards against solid objects larger than 12 mm but offers no protection from water or fine dust, so the unit must be installed in clean, dry control cabinets and away from splash or wash-down zones. For harsher environments, additional enclosures or higher protection rated units will be required.
What spatial footprint and mounting position constraints should installers plan for?
The HMV01.1E-W0120 is compact but still requires clearances for airflow and service (terminal access, blower area). Mounting position must obey specs regarding orientation (vertical/horizontal) and spacing from other heat sources to avoid hotspots — which can degrade performance.
What is the startup behavior and transient performance of the HMV supply under abrupt load changes?
With its capacitance on the DC link (per datasheets) and blower cooling, the unit can buffer moderate sudden load spikes with less voltage droop; however very fast, large transient currents may still lead to voltage dips. Designers need to check dynamic loading of motors and possibly add additional capacitive buffering or oversizing.
What safety interlocks or signal interfaces are available for warning, error, and DC bus status?
According to the instruction manual, there are signal terminals (e.g. UD_1, UD_2, WARN_1, WARN_2) to indicate DC bus voltage status, warnings, and errors, usable in higher level safety logic. These allow external monitoring, interlocking, or shutdown in case of overtemperature, overload, or other fault-conditions.
Common Misspellings
HMV 01.1R-W0018
HMV 1.1R-W0018
HMV01 1R W0018
hmv01.1r-w0018
HMV011RW0018
HMVO1.1R-W0018
HMV1.1R-W0018
Internal Product Review
The Bosch Rexroth Indramat HMV01.1R-W0018 is a regenerative supply unit with 18 kW output power and 700 V DC bus voltage. It offers short circuit protection, reverse polarity protection, and a built-in smart energy mode. This unit is ideal for applications in industrial automation, robotics, and machinery.