Rated Power: 75 kilowatts
Application: DIAX 04 systems
Ambient Temperature for Usage (with rated data): 5 to 45 degrees Celsius
Max Ambient Temperature for Usage (with derated data): 55 degrees Celsius
Storage & Transport Temperature: -30 to 85 degrees Celsius
Max Installation Elevation (without derating): 1000 meters
Max Installation Elevation (with derating): 4000 meters
Overvoltage Limiter Required Elevation: More than 2000 meters
Relative Humidity : Up to 95%
Absolute Humidity: Up to 25 g/m3
Enclosure IP Rating: 10
Cooling Method: Factory fitted blower
Additional Combining Option: GLD DC bus choke
Mains Supply Range: 380 to 480 Volts AC
Type of Operability: Unregulated DC bus voltages