Application: Rexroth DIAX04 AC drive systems
Bleeder Continuous Power: 1 kilowatt
Bleeder Peak Power: 100 kilowatts
Input Voltage: Three-phase 380 to 480 Volts AC
Frequency Range: 50 to 60 Hertz
DC Bus Voltage: 530 to 670 volts
Nominal Power Rating: 18 kilowatts
DC Bus Internal Capacity: 0.8 millifarad
Max DC Bus Capacity: 10 millifarad
Charging Time: 1.6 seconds
DC Bus Short-time Power: 25 kilowatts
Basic Losses: 125 Watts
Power Losses per KW DC bus Continuous Power: 7 watts per kilowatt
Control Voltage Supply Range: 380 to 480 Volts AC
Weight: 28.66 pounds
Dimensions: 496 x 100 x 308 millimeters
Ambient Temperature: 5 to 45 degrees Celsius
Elevation: 0-to-1000-meter
Housing: IP 10 rated.