R911271018 (HVE02.1-W018N)
HVE Power Supply Units
Technical Specifications
Weight
13 kilogram
Operating height
1000 meters above sea level
Temperature range
5 to 45 degrees Celsius
Humidity
95% without condensation
Basic losses
125 kW
Loss at maximum continuous output
250 W
Power losses per kW DC bus continuous power
7 W/kW
Protection category
IP 10
Input Voltage
3 x 380 … 480 V
Frequency range
50-60 Hz
Ambient storage conditions
-30 to 85 degrees Celsius
Power Supply Option
GLD type DC bus chokes (can be connected)
Resistance to heat loss and power failure
HZK Capacitance module (can be connected)
Frequently Asked Questions
What is the rated power of HVE02.1-W018N?
The rated power of HVE02.1-W018N is 18 kW.
What type of cooling method does HVE02.1-W018N use?
HVE02.1-W018N uses internal air cooling with a built-in blower.
What is the protection category of HVE02.1-W018N?
The protection category of HVE02.1-W018N is IP10.
What is the operating frequency range of HVE02.1-W018N?
The HVE02.1-W018N operates between 50 to 60 Hz.
What is the continuous bleeder power of HVE02.1-W018N?
The continuous bleeder power of HVE02.1-W018N is 1 kW.
Common Misspellings
HVE021W018N
HVE02 1 W018N
hve02.1-w018n
HVE02.1W018N
HVE-02.1-W018N
HVE 02.1 W018N
HVE2.1-W018N
Internal Product Review
The HVE02.1-W018N combines durability and high performance, delivering efficient energy management with natural convection cooling. Its low power consumption and strong regeneration capacity make it an environmentally friendly and sustainable option for modern drive systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HVE02.1-W018N.
Exchange
Want to sell your HVE02.1-W018N?